{
  "revision": "MAIN512-whole-base-usability-checked-r113-20261025",
  "updatedUtc": "2026-10-25T16:07:01.609560+00:00",
  "wholeBuildComplete": false,
  "currentKnownImplementationRepairsClosed": true,
  "AssemblyLine": "NEXT and unbuilt",
  "scope": "Current saved 768 by 768 void campus, loaded native machine/ME/power state, controller/storage hardware, travel and habitats, quest boundary, and 1000 surveyed chunks in each of 26 accessible dimensions. This checks the installed base against the retained approved build; it does not assert that every recipe has been run.",
  "currentWholeBaseUsabilityCheck": "sources/current-evidence/MAIN512-whole-base-check-r113-20261025.json",
  "priorCommissioningDetails": "sources/current-evidence/MAIN512-summary-r112-20261024.json",
  "systemsChecked": [
    {
      "system": "Controller and ME channels",
      "result": "Accepted single-chunk controller geometry and P2P wiring retained. Final live MAIN: 32,798 nodes, zero inactive. Workshop four-import leg split onto previously unused face378: new 4/32 channels, original receiver 29/32; all four imports active."
    },
    {
      "system": "Machines, cleanroom and elevations",
      "result": "4,643 GT base tiles inspected; 451 conventional multiblock controllers report formed. The additional LESU is active with 42.96 billion EU; its generic formed flag is not a construction check. All 148 selected basic-machine roots are at Y91 above floor Y90. Higher multiblock offsets match their actual structures. The existing cleanroom at X239 Y95 Z183 is formed, enabled and actively processing."
    },
    {
      "system": "Storage and crafting",
      "result": "100 drives and 1000 original storage cells match saved hardware; actual persisted item, fluid and essentia contents reconciled. All 56 native crafting CPU clusters are active; 6,713 crafting methods and 6,223 craftable item definitions are registered."
    },
    {
      "system": "Power",
      "result": "1,945 selected saved power records checked. Final ME grid is powered; measured average injection about 574,684 AE/t and drain about 529,526 AE/t. Renewable solar generation and saved batteries are present with positive energy. Raw negative globalAvailablePower is not used as a physical-energy measurement."
    },
    {
      "system": "Floor and access",
      "result": "All 589,824 main-floor columns checked across 2,304 chunks. Twenty-one unintended Vortex floor gaps repaired; intentional controller recesses and the Vortex beam shaft retained. Highway bypasses and selected machine approaches are physically clear."
    },
    {
      "system": "Travel and charging",
      "result": "All 57 labeled travel anchors have clear landing/head space. The existing wireless staff charger, owner configuration and energy were checked; saved housing and access were reconciled across outposts."
    },
    {
      "system": "Habitats and oxygen",
      "result": "Current 17-site oxygen/power inspection completed. All 61 identified End hull/power targets restored and normally saved; full 1,148-cell geometry and 26 service records verified. Both End sealers naturally reached sealed, powered operation and near-full/full oxygen."
    },
    {
      "system": "Maps and quest boundary",
      "result": "All 26,000 surveyed chunks and primary rendered maps reconciled across 26 dimensions. All 120 selected restored prerequisite quests remain complete. Assembly Line remains the next unbuilt quest; no quest progress was added during this check."
    }
  ],
  "currentRepairs": [
    {
      "id": "VORTEX-FLOOR-21",
      "state": "Restored 21 off-axis main-floor blocks; independent normal-save proof passed. The central beam shaft and original aura nodes were preserved."
    },
    {
      "id": "MANUAL-MAINTENANCE-77",
      "state": "Serviced 77 existing manual maintenance hatches with ordinary tools/duct tape; all six flags normally saved. Ordinary maintenance wear remains part of the game."
    },
    {
      "id": "END-HABITAT-61",
      "state": "Restored 61 missing End hull/power cells, including two actual power wires; verified full geometry, ownership and natural sealed oxygen operation in the normal save."
    },
    {
      "id": "WORKSHOP-ME-CHANNELS",
      "state": "Replaced one overfull Dense attachment with one normal local wireless receiver paired to unused wall endpoint378. Four existing imports now have channels; original filters, core geometry and P2P configuration retained. Independent normal-save check passed: all 64 original links retained, new 65th pairing reciprocal, all controller/P2P geometry and four import configurations preserved."
    }
  ],
  "evidenceLimits": [
    "These are saved-world and actual running-game background checks; no screen control or player movement was used.",
    "Every individual recipe and a human walkthrough were not exercised. Existing commissioning evidence remains linked separately.",
    "No restart, forced save, artificial power, forced ticks or quest completion was used. Historical cause of the End damage was not established."
  ]
}
